ÄÚÀÎÇü ¸®Æ¬ÀüÁö > FDK > FDK CR2430-F1ST3SF-V2P(3V 280mAh)

FDK CR2430-F1ST3SF-V2P(3V 280mAh)
Á¦Á¶È¸»ç : FDK
ÆǸŰ¡°Ý : 2,000¿ø
¼ö·® EA
 
¿ø»êÁö : ÀϺ»
»óÇ°¸í : FDK CR2430-F1ST3SF-V2P(3V 280mAh)
 
     
Nominal Voltage(Àü ¾Ð) 3.0V
Rated Capacity(¿ë ·®) 280mAh to 2.0V at 20¡ÆC (68F)
Average Weight(¹« °Ô) 4.6g (0.162oz)
Volume 1.4cm3 (0.086in.3)
Operating Temp. Range -20¡ÆC to 60¡ÆC (-4F to 140F)





1. Service out-put(load characteristics)
Continuous discharge, E.P.V:2.5V, Temp.:20¡¾2¡ÆC
Load
15kW 30kW
1513hours 3049hours
Average of 10 batteries
2. Service out-put(Temperature characteristics)
15kWcontinuous discharge, E.P.V.:2.5V
Temperature
-20¡ÆC 20¡ÆC 60¡ÆC
1354hours 1513hours 1436hours
Average of 10 batteries
3. Storage characteristics at high temperature(60¡ÆC, ordinary humidity)
Item Storage periods
Initial after 40 days after 80 days
Off-load-voltage (V) 3.189 3.221 3.213
Internal resistance (W) 4.2 4.6 4.9
Leakage (pcs) 0 0 0
Service Out-put at 15kW
Continuous discharge (hours)
E.P.V.:2.5V
1513 - -
Test temp.:20¡¾2¡ÆC, Average of 10 batteries
4. Short circuit characteristics
(1) Temperature of battery surface


(2) Change of off-load voltage after short circuit


(3) Shape, Dimension, Appearance
No change is recognized for 80minutes. (temp.:20¡¾2¡ÆC)
5. Over-discharge characteristics
Test temp.:20¡¾2¡ÆC
Test method Test result
The discharge is further continued for 20days at 15kW load after the voltage has become less than the end-point voltage(2.5V) Appearance:No change
10 batteries are tested.
6. Charge characteristics
Test temp.:20¡¾2¡ÆC
Charge current Charging time Test result
0.37mA 24hours Appearance:No change
10 batteries are tested.
7. Heat shock test
Range of temperature:-10~+60¡ÆC, Time:each for 1 hour
Item Initial After 100 cycles
Off-load-voltage (V) 3.178 3.214
Internal resistance (W) 4.2 4.2
Leakage (pcs.) - 0
Measuring temp.:20¡¾2¡ÆC, Average of 10 batteries
Measurement of internal resistance is done by 1kHz alternating current.
Leakage proof is done by visual check.
8. Vibration test
Amplitude:1.5mm, Frequency:10~55Hz,
Time:X,Y,Z direction, each for 90 minutes
Item Initial After 100 cycles
Off-load-voltage (V) 3.220 3.219
Internal resistance (W) 4.5 4.4
Leakage (pcs.) - 0
Average of 10 batteries
Measurement of internal resistance is done by 1kHz alternating current.
 
 



»óÈ£¸í : (ÁÖ)È«ÀÍ¿¡½º¿¥ »ç¾÷ÀÚµî·Ï¹øÈ£ : 113-86-60462 [»ç¾÷ÀÚÁ¤º¸È®ÀÎ] Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦ 2012-¼­¿ï±¸·Î-0721 È£
´ëÇ¥ : ¹Ú¿µ³² »ç¾÷Àå¼ÒÀçÁö : ¼­¿ï ±¸·Î±¸ ±¸·Î2µ¿ 1258 Áß¾ÓÀ¯Åë´ÜÁö ¸¶µ¿ 1314~1315È£
ÀüÈ­ : TEL : 02-6679-3505~7, FAX : 02-2618-7078 °³ÀÎÁ¤º¸´ã´çÀÚ : ¹Ú¿µ³²
[ȸ»ç¼Ò°³] [ÀÌ¿ë¾È³»] [ÀÌ¿ë¾à°ü] [°³ÀÎÁ¤º¸Ãë±Þ¹æħ]
Copyright ¨Ï (ÁÖ)È«ÀÍ¿¡½º¿¥ All Rights Reserved.